On a metal boat the electrical system is either unbonded, with nothing touching the hull, or bonded, with battery negative connected to the hull at a single point. If a positive wire then touches the hull, the current has a way back to battery negative and blows a fuse, rather than finding some other path. Every device still has its own negative wire back to the battery.

In this video I bond Renko's steel hull to battery negative through the electrical board, the only place it's connected, and check the continuity between them is less than 1 ohm. Then I do a silver half-cell test: a piece of silver hung in the water on the multimeter's negative lead, and the positive on a fitting welded to the hull. I read about minus 1 volt, which the chart I use says is adequate protection for steel but at the high end, and too high for aluminium. Two more anodes and the hull would be overprotected, which can lift the paint and cause rust.

Checking for current

With the multimeter on milliamps, I check for any current flowing between the bonding strap and the hull. There's none, which is good.

Bonded or unbonded

Planning the trawler's electrics: an unbonded system is very hard to achieve, and has to be tested often to make sure a single screw hasn't made a second path to the hull. I go with a single connection to the hull, with every device wired directly back to battery negative.